Bell & Gossett
189596 Bell & Gossett B-400, B-500 & B-600 Series LA Bladder Only
- MPN:
- 189596
- Condition:
- New
- Availability:
- Please Contact Us For Availability
- Shipping:
- Calculated at Checkout
Description
189596 Bell & Gossett B-400, B-500 & B-600 Series LA Bladder Only.
Bell & Gossett Pre-charged Bladder & Diaphragm Tanks ASME (B,D,B-LA). Please Contact Us For Lead Time & Pricing.
If you have questions you can also email your request to us at: Sales@NationalPumpSupply.com.
- Bell & Gossett Pre-charged Bladder & Diaphragm Tanks ASME (B,D,B-LA) Brochure
- Bell & Gossett Pre-charged Bladder & Diaphragm Tanks ASME (B,D,B-LA) Instruction/Operating Manual
- Bell & Gossett Series "B" (ASME) Pressurized Expansion Tanks Vertical Submittal Sheet
- Bell & Gossett Series "B" (ASME) High Pressure Models Pressurized Expansion Tanks Submittal Sheet
- Bell & Gossett Series "B-LA" (ASME) Pressurized Expansion Tanks Vertical Not For Potable Water Systems Submittal Sheet
- Bell & Gossett Series "B-LA" (ASME) Pressurized Expansion Tanks Vertical with Seismic Restraint Not For Potable Water Systems Submittal Sheet
- Bell & Gossett Series "D" (ASME) Pressurized Expansion Tanks Horizontal Not For Potable Water Systems Submittal Sheet
- Bell & Gossett Series "D" (ASME) Pressurized Expansion Tanks Vertical Not For Potable Water Systems Submittal Sheet
- Bell & Gossett Series "D" (ASME) Pressurized Expansion Tanks Vertical with Sight Glass and Seismic Restraints Not For Potable Water Systems Submittal Sheet
Bell & Gossett Pre-charged Expansion Tanks contain either a bladder or a diaphragm to separate the air charge from the system water. Tanks are design to absorb the expansion forces of heating/cooling system water while maintaining proper system pressurization under varying operating conditions.
Series B
- ASME Section VIII, Division 1 design and constructed
- Heavy duty full acceptance replaceable butyl bladder
- Sizes: 53 – 3,963 gallon
- Factory pre-charge to 12 PSI, adjustable in the field
- High pressure models up to 250 PSI available
- Seismic restraints available
- California-code sight glass available
Series D
- ASME Section VIII, Division 1 design and constructed
- Economical fixed butyl diaphragm
- Sizes: 8 – 211 gallon
- Vertical and horizontal designs
- Factory pre-charge to 12 PSI, adjustable in the field
- Seismic restraints available
- California-code sight glass available
Series B-LA
- ASME Section VIII, Division 1 design and constructed
- Economical heavy duty replaceable butyl bladder
- Sizes: 10 – 158 gallon
- Factory pre-charge to 12 PSI, adjustable in the field–
- Seismic restraints available
- California-code sight glass available
Please contact us for lead time.
Warranty Information
Warranty: Quoted prices include standard factory warranties. Warranty requires install, start-up and operation as per the manufacturers IOM.
Job Site Assistance: By Others
Start-Up: By Others
Commissioning: By Others: These services, if a project requires start up, they are responsibility of contractor or commissioning agent. Owner training assistance, as outlined in any equipment specifications the responsible of the commissioning agent.
Clarifications & Exclusions
'ALTERNATES' are offered for consideration and will always be subject to the engineer's and owners approval. Excludes any seismic calculations or supports, coatings other than factory standard.
Terms: prices are quoted are "each" (unless stated otherwise) and FOB point of origin with no freight allowed freight ships via common ground carrier, and inside continental US Only - any special shipping requirements to be responsibility of purchaser. We offer all prices less tax, with a validity of 30 days from the date quoted and all sales are final. Once items have shipped and left the warehouse National Pump Supply is not responsible for any damage caused during the shipping process. You must contact the shipper directly and file a claim with the shipping company.
Lead Time: All prices offered are based on standard factory lead times (or) as stated within quotation. Expedited shipments may be available at an additional charge. Contact your Sales Engineer for the ETA of any specific equipment on any order or quotation.
View AllClose